Outdoor 19 Rack Enclosure Rectifier System , Base Station Telecom Power System
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V |
Brand Name: ESTEL | Output Voltage: DC48V |
Model Number: GPE4890B | Output Current: 90A |
Product Name: Telecom Rectifier System | Input Frequency 45~65Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Input Current: 29.7A |
Installation Mode: cabinet 19” rack | Power Factor: 0.98 |
Application: outdoor telecom cabinet | Components: 3×30A rectifier module, 1×monitoring module, power distribution |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, , T/T, Western Union |
Supply Ability: | 10,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
1. Application
(1) Small scale program controlled exchanger
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
2. Features
(1) Adoption of active power factor compensation technology with factor >0.98
(2) Wide operating range of AC input voltage: 90~280Vac
(3) Operating temperature range:-25°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥90%
(5) Perfect battery management, charge&discharge management, battery temperature compensation, low voltage protection, battery capacity test
(6) Hot-swappable
(7) Input over/under voltage protection
(8) Output over voltage protection
(9) Output over current protection
(10) Output short circuit protection
(11) Auto current sharing, parallel operation
(12) Embedded mounted
3. GPE4890B System Configuration
GPE4890B consists of distribution unit, rectifier module (up to 3 sets) and 1 monitoring module. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Power Distribution |
Optional 1 | GPR4830A | GPM48D (Without Ethernet Port) | GPE4890B: DC Output: 40A×4 (load); Battery Output: 70A×1 (battery) |
Optional 2 | GPR4810A | ||
Optional 3 | GPR4815A | ||
Optional 4 | GPR4820A |
Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under 42V±0.5V, the monitoring module reports battery under voltage alarm signal and cuts off the load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).
Input | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 280 | Vac | |
Input frequency | 45 | 50 | 65 | Hz | |
Input current | 29.7 | A | |||
Power factor | 0.98 |
Output | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Output voltage range | -42 | -53.5 | -58 | Vdc | |
Output current range | 0 | 90 | A | 176~280VAC | |
0 | 45 | A | 90~175VAC | ||
Ripple (Vp-p) | 200 | mv | At rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz. | ||
Output efficiency | 90 | 92 | % | 220Vac input | |
83 | 85 | % | 110Vac input | ||
Regulation | ±1 | % | |||
Load regulation | ±1 | % | |||
Line regulation | ±1 | % |
Insulation rating | ||
Parameter | Min | Remark |
Input - output | 2121Vdc/10mA//1min | |
Input-chassis | 2121Vdc/10mA//1min | |
Output - chassis | 750Vdc/10mA//1min | |
Insulation resistance | At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ |
Ambient requirements | |||||
Parameters | Min. | Typical | Max. | Unit | Remark |
Operating temp | -25 | +55 | °C | ≥ 55°C, output with derating power | |
Storage tempStorage temperature | -40 | +80 | °C | ||
Humidity | 10 | 90 | % | Relative humidity, no condensing | |
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 3000 | m | ||
Cooling method | Forced cooling with fan |
Mechanical specifications | |
Dimensions (Overall) | 482.6mm×255mm×86.1mm |
Weight(kg) (Overall) | ≤11kg (Inclusive of module) ≤5.175kg (Frame + Distribution, exclusive of module) |
6. Electric Connection
Chassis connects with external electric through system interface board. As shown in figure below:
Connector Instruction:
Item | Remark |
Remote monitoring of the host | The host can conduct enquiries, settings and control upon the monitoring and realize the remote message, remote sense and remote control. |
Rectifier management by monitoring module | To send controlling orders or to get data from the rectifier module via RS485 communication. |
Battery management | To manage low voltage, power down, equalizing/float charge, temperature compensation of the battery. |
Output management by monitoring module | To inspect and control the system |
LED indicator | Signal indication |
6 way dry contact output | Dry contact setting |
COM port signal definition | |
LCD Display | Set and revise menu |
For details, please refer to specifications of “GPM48DI”. |
8. Rectifier Module Property
Item | Unit | Min. | Typical | Max. | Remarks |
AC input voltage | Vac | 90 | 220 | 280 | |
AC input voltage frequency | Hz | 45 | 50 | 65 | Rated load |
Input power factor | 0.98 | Rated voltage/ rated load | |||
Output voltage range | Vdc | -42 | -54 | -58 | |
Output current | A | 0 | 30 | 176~290V ac Input | |
Output voltage regulation | ±1% | ||||
Ripple (Vp-p) | mV | 200 | With 0.1uF filmy capacitor and 10uF high frequency electrolyte capacitor, oscilloscope band width of 20MHz. | ||
Output power | W | 0 | 1600 | 176-280V Input | |
W | 0 | 800 | 90-175V Input | ||
Output efficiency | % | 91 | 220V AC Input | ||
% | 83 | 110V AC Input | |||
Input over-voltage protection | Vac | 285 | 305 | Tested with 15A, auto recoverable | |
Input over-voltage recovery set point | Vac | 280 | Hysteresis not less than 5V. | ||
Input under-voltage protection | Vac | 85 | Tested with 4A, auto recoverable | ||
Input under-voltage recovery set point | Vac | 90 | Hysteresis not less than 5V. | ||
Output over-voltage protection set point | V | -58.5 | -59 | -61.5 | Lock up |
Output current limiting | A | 32 | 33 | 34 | Auto recoverable |
Short circuit protection | A | Long-term short circuit endurable; Hiccup when short circuit detected; Auto recoverable | |||
Thermal protection | Auto recoverable under ambient temperature of 65°C. | ||||
For details, please refer to specifications of “GPR4830A1”. |
9. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by
train, etc.
Besides the following delivery agent, we can also look for the
delivery agent with the best price in china if you need us to do
for you.
10. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Tianjin Estel Electronic Science and Technology Co.,Ltd
Introduction
Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and technology innovative company, we engage in the R&D, manufacture, and sales of telecommunication equipment. Estel has a well-established team of technical and management experts who can meet customers’ specific needs accurately.
The base station integrated solutions and products include outdoor integrated telecom equipment cabinet, battery cabinet, RRU cabinet, power supply cabinet, environment monitoring system, TEC peltier air conditioner, AC220V compressor air conditioner, DC48V variable frequency air conditioner, heat exchanger, rectifier, UPS, embedded telecom power system etc. All the above solutions and products can be custom made.
Our products and solutions have been deployed all over China. Our main domestic customers are China Telecom, China Mobile, China Unicom, State Grid, Shenzhen / Beijing Metro and Huawei / ZTE etc. In addition, our products have been exported to Europe, North America, South America, Central America, Southeast Asia, Africa, Australia, Mid East countries, etc.
“ Customers First, Quality First ” is always our principle. We have attained many certifications, such as ISO9001, ISO14001, OHSAS18001, CE, UL, FCC etc. AS a telecom integrated solutions / energy saving system integrator in China, We have strong advantages in technology competitiveness, management competitiveness ,service competitiveness and price competitiveness. Through many years of experiences in design, production and implementation of different projects around the world, we have gained great reputation. Relying on professional technique and strict quality control, we will continuously offer high cost-effective products and solutions to our respectable customers globally. We will always try our best to meet customers’ need and requirement.
Company Capability
Trade & Market
Main Markets | Total Revenue (%) |
Domestic Market | 50.00% |
Africa | 15.00% |
Southeast Asia | 10.00% |
South America | 5.00% |
Central America | 5.00% |
Australia | 3.00% |
Mid East | 3.00% |
North America | 2.00% |
Southern Europe | 2.00% |
Eastern Europe | 1.50% |
Northern Europe | 1.00% |
Western Europe | 1.00% |
South Asia | 1.00% |
Eastern Asia | 0.50% |