150A Small Scale Program Telecom Rectifier System With Perfect Battery Management
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V |
Brand Name: ESTEL | Output Voltage: DC48V |
Model Number: GPE48150 | Max Output Current: 150A |
Product Name: Telecom Rectifier System | Input Frequency: 45~65Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Max. Input Current: 60A |
Installation Mode: 19” rack | Power Factor: 0.99 |
Application: outdoor telecom cabinet | Components: 5×30A rectifier module, 1×monitoring module, power distribution |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 20,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
GPE48150 consists of two layers of 1U insert frame. The first layer consists of rectifier module (at least 1 set, up to 2 sets) and 1monitoring module . The second layer frame consists of rectifier module, and can be up to 3 sets. The second layer is optional, depending on the customer. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Power Distribution |
Standard | GPR4830A R01 | GPM48VI | Load output 1 way |
AC power (single-phase or three-phase) get into the rectifier module through the AC input terminal (L1, L2, L3, N). OUT+, OUT- is DC power system output terminal. User load and the battery access to the power system DC output terminal through the power-down contactor. load power-down contactor is normally closed under situation of no trigger, battery power-down contactor is normally open under situation of no trigger.
In normal conditions, various parameters of rectifier module and power distribution units are controlled by the monitoring module, and work according to the predetermined parameters or user commands. If there is a power failure, at this time system will be powered by battery, with the discharge of the battery, battery terminal voltage begin to decline, when the battery voltage is lower than 46.2V (adjustable), the monitoring module reports DC undervoltage alarm signal, when the battery voltage drops to 45.6V (adjustable), the monitoring module controls the load power-down contactor, turning off the load power supply. When the external power recovery, the system will restore the normal working state of the battery and the load (the above monitoring data is the system default value, the user can re set).
Input | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 280 | Vac | |
Input frequency | 45 | 50 | 65 | Hz | |
Input current | 60 | A | |||
Power factor | 0.99 | Rated input, full load output |
Output | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Output voltage range | 42 | 53.5 | 58 | Vdc | |
Output current range | 0 | 150 | A | 176~280VAC | |
0 | 75 | A | 90~175VAC | ||
Single module current limit point | 31 | 33 | 35 | A | System current limit point = Single module current limit point* module quantity |
Ripple (Vp-p) | 200 | mv | At rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz. | ||
Output efficiency | 88 | 90 | % | 220Vac input, output 120A | |
83 | 85 | % | 110Vac input, output 60A | ||
Regulation | ±2 | % | |||
Load regulation | ±2 | % | |||
Line regulation | ±1 | % |
Insulation rating | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input-chassis | 2121 | Vdc | |||
Input - output | 4242 | Vdc | |||
Output - chassis | 710 | Vdc | |||
Insulation resistance | At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ |
Ambient requirements | |||||
Parameters | Min. | Typical | Max. | Unit | Remark |
Operating temp | -25 | 55 | °C | When ≥55°C, derating output | |
Storage tempStorage temperature | -40 | 80 | °C | ||
Relative humidity | 10 | 90 | % | no condensing | |
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 3000 | m | ||
Cooling method | Forced cooling with fan |
Mechanical specifications | |
Dimensions (mm) | 482.6mm×304mm×87.3mm |
Weight (kg) | ≤11kg (Inclusive of module) ≤5.175kg (Frame + Distribution, exclusive of module) |
Chassis connects with external electric through system interface board. As shown in figure below:
Wiring Terminal Instruction:
AC input port is used for connecting AC input.
5. Application
(1) Small scale program controlled exchangers
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
6. Features
(1) Adoption of active power factor compensation technology with factor >0.99
(2) Wide operating range of AC input voltage: 90~280Vac
(3) Operating temperature range: -25°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥88%
(5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.
(6) Hot-swappable
(7) Input over/under voltage protection
(8) Output over voltage protection
(9) Output over current protection
(10) Output short circuit protection
(11) Auto current sharing, parallel output
(12) Embedded mounting
7. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
8. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Tianjin Estel Electronic Science and Technology Co.,Ltd
Introduction
Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and technology innovative company, we engage in the R&D, manufacture, and sales of telecommunication equipment. Estel has a well-established team of technical and management experts who can meet customers’ specific needs accurately.
The base station integrated solutions and products include outdoor integrated telecom equipment cabinet, battery cabinet, RRU cabinet, power supply cabinet, environment monitoring system, TEC peltier air conditioner, AC220V compressor air conditioner, DC48V variable frequency air conditioner, heat exchanger, rectifier, UPS, embedded telecom power system etc. All the above solutions and products can be custom made.
Our products and solutions have been deployed all over China. Our main domestic customers are China Telecom, China Mobile, China Unicom, State Grid, Shenzhen / Beijing Metro and Huawei / ZTE etc. In addition, our products have been exported to Europe, North America, South America, Central America, Southeast Asia, Africa, Australia, Mid East countries, etc.
“ Customers First, Quality First ” is always our principle. We have attained many certifications, such as ISO9001, ISO14001, OHSAS18001, CE, UL, FCC etc. AS a telecom integrated solutions / energy saving system integrator in China, We have strong advantages in technology competitiveness, management competitiveness ,service competitiveness and price competitiveness. Through many years of experiences in design, production and implementation of different projects around the world, we have gained great reputation. Relying on professional technique and strict quality control, we will continuously offer high cost-effective products and solutions to our respectable customers globally. We will always try our best to meet customers’ need and requirement.
Company Capability
Trade & Market
Main Markets | Total Revenue (%) |
Domestic Market | 50.00% |
Africa | 15.00% |
Southeast Asia | 10.00% |
South America | 5.00% |
Central America | 5.00% |
Australia | 3.00% |
Mid East | 3.00% |
North America | 2.00% |
Southern Europe | 2.00% |
Eastern Europe | 1.50% |
Northern Europe | 1.00% |
Western Europe | 1.00% |
South Asia | 1.00% |
Eastern Asia | 0.50% |