Home /

0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System

Send your message to this supplier
*From:
Your email address is incorrect!
To:Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap 0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System from wholesalers
  • Buy cheap 0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System from wholesalers

0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System

Ask Latest Price
Brand Name:Shenzhen Chengtiantai
Model Number:YTTW
Certification:CCC
Price:on request
Payment Terms:L/C, T/T
Supply Ability:50,000 m/day
Delivery Time:7 / 15 working days
Company Data
Verified Supplier
Contact Person Annie Chen
Business Type: Manufacturer Exporter
Officials: No.130 Jingsong 3rd road, Lisonglang Community, Gongming Street, Guangming District, Shenzhen, Guangdong, China, 518000
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

Fire resistance cable YTTW


YTTW cable is designed for aboveground applications.


Engineered to replace conduit and wire applications, this all-in-one cable assembly offers fewer installation steps.


The copper metallic sheath protects the conductors from damage before,during and after installation and provides overall flexibility not available with a conduit.


0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System


— Flame Retardant
— High Operating Temperatures

LSOH Halogen-free
Great Mechanical Strength
Competitive Installed Cost
Public Places

Our YTTW cables provide outstanding electrical and fire-proof properties, and are halogen free.


The design, construction and testing are compliant with international standard IEC60502 and testing standard EN 50200 (PH-90),with standing temperatures of 840 °C for 90 minutes, which means they are capable of remaining in working order despite the most extreme fire conditions. Hence they are known as FIRE RESISTANT cables.


This type of cable is made up of single and multi-cores 600/1000V cables Service Temperature 90°C Emergency Overload Temperature 105°C Short-Circuit Temperature 250°C


Installation of these cables is essential in safety circuits (detection and alarm circuits,evacuation and fire-fighting systems).


STANDARDS:
NationalInternational
ConstructionGB/T 12706IEC 60502
Non fire-propagatingGB/T 18380.3IEC 60332-3
Low opacity of smoke emittedGB/T 17651.2IEC 61034-2
Fire-resistantGB/T 12666.6IEC 60331
Low acidity and corrosiveness of gasesGB/T 17650.2IEC 60754-2
Halogen freeGB/T 17650.2IEC 60754-1
Non flame-propagatingGB/T 18380.1IEC 60332-1-2

Rated working voltage:


–​ Light Duty: 500 V

–​ Testing Voltage (50 Hz): 2500 V - 15 min


–​ Heavy Duty: 750 V

–​ Testing Voltage (50 Hz): 2000 V - 15 min


Cable structure
0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm SystemConductorStranded copper conductor class 2
Insulationmica tape1, flame retardant
FillerGlass yarns
core wrapingCore wrapping with glass-fibre tape as flame-protection
SheathCorrugated Copper
Outer covering (Optional)Anticorrosion Outer Sheath PVC

USAGE CHARACTERISTICS
Service Temperature90°C
Emergency Overload Temperature105°C
Short-Circuit Temperature250°C
Laying Temperatureshould not be lower than 0°C
Minimum bending radius when layingSingle core: r = 6 x cable outer diameter
Sheath colourThe standard color is orange, other colors are available.

SINGLE CONDUCTOR

Nominal

cross

Section

Nominal insulation thickness

Thickness of

metallic

sheath

Outer

Diameter

approx.

current

carrying

capacity

Voltage

drop
cos μ= 0,8

mm2mmmmmmAV/A.km
1×1.00.800.403.53-23.10
1×1.50.800.403.783215.40
1×2.50.800.404.18429.48
1×4.00.800.504.85565.90
1×6.00.800.505.36703.90
1×101.000.507.02972.33
1×161.000.608.241251.47
1×251.000.609.561650.92
1×351.000.6010.702000.67
1×501.200.7012.602450.49
1×701.200.7014.403050.34
1×951.200.8016.503750.25
1×1201.200.8018.144350.20
1×1501.400.8020.155000.16
1×1851.400.9022.105800.13
1×2401.400.9024.856850.10
1×3001.601.0027.707950.08
1×4001.601.0030.409300.06

2 CONDUCTOR


Nominal

cross

Section

Nominal Insulation thickness

Thickness of

metallic

sheath

Outer

Diameter

approx.

Ampacity

Voltage

drop
cos μ= 0,8

mm2mmmmmmAV/A.km
2×2.50.800.506.963318.96
2×4.00.800.608.104411.8
2×6.00.800.609.12577.8
2×101.000.7012.44784.66
2×161.000.7014.481042.86
2×251.000.8017.321352.52
2×351.100.8019.901682.24
2×501.200.9023.002041.64
2×701.201.0026.802631.42
2×951.201.0030.603201.08
2×1201.201.0033.883730.98

THREE CONDUCTOR


Nominal
cross
Section

Nominal insulation thicknessThickness of

metallic

sheath

Outer

Diameter

approx.

Ampacity

Voltage

drop
cos μ= 0,8

mm2mmmmmmAV/A.km
3×2.50.80.607.562916.4
3×4.00.80.608.573810.2
3×6.00.80.609.67466.74
3×101.00.7013.22654.03
3×161.00.7015.42852.54
3×251.00.8018.461181.59
3×351.10.8021.431501.16
3×501.20.9024.551920.85
3×701.21.0028.632280.59
3×951.21.0032.722730.43
3×1201.21.0036.263140.35

FOUR CONDUCTOR


Nominal
cross
Section
Nominal insulation thicknessThickness of

metallic

sheath

Outer

Diameter

approx.

AmpacityVoltage

drop
cos μ= 0,8

mm2MmmmmmAV/A.km
4×6.00.80.6010.59466.74
4×101.00.7014.52654.03
4×161.00.8017.18852.54
4×251.00.9020.571181.59
4×351.11.0023.861501.16
4×501.21.0027.341920.85
4×701.21.0031.692280.59
4×951.21.0036.272730.43

3+1 CORE
Nominal
cross
Section
Nominal insulation thicknessThickness of

metallic

sheath

Outer

Diameter

approx.

AmpacityVoltage

drop
cos μ= 0,8

mm2mmmmmmAV/A.km
3×16+1×101.00.8016.56852.54
3×25+1×161.00.9019.771181.59
3×35+1×161.11.0022.181501.16
3×50+1×251.21.0025.871920.85
3×70+1×351.21.0029.812280.59
3×90+1×501.21.0034.042730.43

Notes:


Ampacities based on 90°C conductor temperature and 40°C ambient temperature according to IEC 287 standard


The voltage drop based on conductor temperature 90°C is on the high side calculated only for reference


When the cable adopt compressed cores, diameter of cable should be 95% of normal diameter, diameter of metallic sheath should be adjusted correspondingly. When enhancing the insulation, outer diameter of cable is increased for about 5%.


1 Glass cloth reinforced Muscovite mica tape

2 Current ratings in Ampere (A) up to 30° C ambient temperature


0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System


Company Profile

Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

                            

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Flame Retardant Cable 0.6/1kV IEC 601034 Fire Resistant Insulation Orange Sheath For Fireproof wholesale

Flame Retardant Cable 0.6/1kV IEC 601034 Fire Resistant Insulation Orange Sheath For Fireproof

China Electric Fire Resistant Power Cable , Mineral Insulated Cable IEC60502 Standard wholesale

Electric Fire Resistant Power Cable , Mineral Insulated Cable IEC60502 Standard

China IEC60502 Standard Electrical Mineral Insulated Power Cable Fire Resistant wholesale

IEC60502 Standard Electrical Mineral Insulated Power Cable Fire Resistant

China Fire Resistant Electrical Mineral Insulated Power Cable IEC60502 Standard wholesale

Fire Resistant Electrical Mineral Insulated Power Cable IEC60502 Standard

China 0.6 / 1kV Fire Resistant Power Cable , Electrical Mineral Insulated Wire Cable wholesale

0.6 / 1kV Fire Resistant Power Cable , Electrical Mineral Insulated Wire Cable

China 0.6 / 1KV High Safety Fire Resistant Mica Tape Cable 4 Core For Public Places wholesale

0.6 / 1KV High Safety Fire Resistant Mica Tape Cable 4 Core For Public Places

China Light / Heavy Duty Fire Resistant Cable Four Core Copper Metallic Sheath wholesale

Light / Heavy Duty Fire Resistant Cable Four Core Copper Metallic Sheath

China 2 Core Fire Resistant Cable Mineral Insulated Bare Copper Class 2 Conductor wholesale

2 Core Fire Resistant Cable Mineral Insulated Bare Copper Class 2 Conductor

China 600/1000V High Safety Fire Resistant Cable 4 Core For Public Places wholesale

600/1000V High Safety Fire Resistant Cable 4 Core For Public Places

China YTTW Fire resistance Electrical Cable , Mica Tape Insulation Metallic Sheathed Cable wholesale

YTTW Fire resistance Electrical Cable , Mica Tape Insulation Metallic Sheathed Cable

China Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions wholesale

Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions

Inquiry Cart 0