Home /

Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions

Send your message to this supplier
*From:
Your email address is incorrect!
To:Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions from wholesalers
  • Buy cheap Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions from wholesalers

Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions

Ask Latest Price
Brand Name:Chengtiantai Cable
Model Number:WDZ-YJV
Certification:CB, CE
Price:On request
Payment Terms:L/C, T/T
Delivery Time:15 working days
Company Data
Verified Supplier
Contact Person Annie Chen
Business Type: Manufacturer Exporter
Officials: No.130 Jingsong 3rd road, Lisonglang Community, Gongming Street, Guangming District, Shenzhen, Guangdong, China, 518000
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

Fire resistant cable 4 core 0.6/1 kV Cu-conductor, Mica-tape, XLPE Insulated, LSZH sheathed


Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.


Physical and Electrical Characteristics:


No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
4×41.01.814.933930384.61
4×61.01.816.143638483.08
4×101.01.819.366953661.83
4×161.01.821.895370861.15
4×251.21.826.01374941120.73
4×351.21.828.718101161350.52
4×501.41.929.523121391610.39
4×701.42.133.031051772020.27
4×951.62.238.141792172400.19
4×1201.62.441.151852542740.15
4×1501.82.545.864142943090.12
4×1852.02.750.579013373460.10
4×2402.22.955.7102494014030.08
4×3002.43.163.4133654704590.06


INSTALLATION METHOD DETAILS


Four Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy Distributions
A1 – Thermally insolated wall (Single-core)A2 – Thermally insolated wall (multi-core)B1 – Apparent electroduct (Single-core)B2 – Apparent electroduct (multi-core)
Four Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy Distributions
B1 – Electroduct in brickwork (Single-core)B1 – Electroduct in brickwork (multi-core)C – On the wall C – On the ceiling
Four Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy Distributions
C – Non-perforated trayF – Perforated tray (Single-core)F – Perforated tray (multi-core)F –Suspended (Single-core)
Four Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy Distributions
E – Suspended (multi-core)B2 – Construction spaceB2 – Construction spaceB1 – Electroduct (Single-core)
Four Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy Distributions
B2 – Electroduct (Multi-core)B2 – Closed raceway embedded in floor (multi-core)B2 – Closed raceway embedded in floor (multi-core)B1 – Ventilated raceway embedded in floor
Four Core Fire Resistant Electrical Wire Cable For Local Energy DistributionsFour Core Fire Resistant Electrical Wire Cable For Local Energy Distributions
C – Embedded in the brickworkD – Buried in additional mechanical protection

Cable Drum Data


CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 605021000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300

RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.


We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.


Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106


WARRANTY


For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Company Profile

Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

                            

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Flame Retardant Cable 0.6/1kV IEC 601034 Fire Resistant Insulation Orange Sheath For Fireproof wholesale

Flame Retardant Cable 0.6/1kV IEC 601034 Fire Resistant Insulation Orange Sheath For Fireproof

China Electric Fire Resistant Power Cable , Mineral Insulated Cable IEC60502 Standard wholesale

Electric Fire Resistant Power Cable , Mineral Insulated Cable IEC60502 Standard

China IEC60502 Standard Electrical Mineral Insulated Power Cable Fire Resistant wholesale

IEC60502 Standard Electrical Mineral Insulated Power Cable Fire Resistant

China Fire Resistant Electrical Mineral Insulated Power Cable IEC60502 Standard wholesale

Fire Resistant Electrical Mineral Insulated Power Cable IEC60502 Standard

China 0.6 / 1kV Fire Resistant Power Cable , Electrical Mineral Insulated Wire Cable wholesale

0.6 / 1kV Fire Resistant Power Cable , Electrical Mineral Insulated Wire Cable

China 0.6 / 1KV High Safety Fire Resistant Mica Tape Cable 4 Core For Public Places wholesale

0.6 / 1KV High Safety Fire Resistant Mica Tape Cable 4 Core For Public Places

China Light / Heavy Duty Fire Resistant Cable Four Core Copper Metallic Sheath wholesale

Light / Heavy Duty Fire Resistant Cable Four Core Copper Metallic Sheath

China 2 Core Fire Resistant Cable Mineral Insulated Bare Copper Class 2 Conductor wholesale

2 Core Fire Resistant Cable Mineral Insulated Bare Copper Class 2 Conductor

China 600/1000V High Safety Fire Resistant Cable 4 Core For Public Places wholesale

600/1000V High Safety Fire Resistant Cable 4 Core For Public Places

China YTTW Fire resistance Electrical Cable , Mica Tape Insulation Metallic Sheathed Cable wholesale

YTTW Fire resistance Electrical Cable , Mica Tape Insulation Metallic Sheathed Cable

China Electric Mineral Fire Resistant Insulated Power Cable IEC60502 Standard wholesale

Electric Mineral Fire Resistant Insulated Power Cable IEC60502 Standard

Inquiry Cart 0