UL910 covers the test method for determining values of flame-propagation distance and optical smoke density for electrical and optical-fiber cables that are intended to be installed in ducts, plenums, and other spaces used to transport environmental air without the cables being enclosed in raceways in those spaces.
Technical parameters
1.The fire test chamber is exactly the same as that of UL fire lab.
2.The fire test chamber is a rectangular horizontal duct with a
removable lid.
3.The sides and base of the chamber are lined with an insulating
firebrick.
4.One side of the fire testing chamber is provided with double
quartz observation windows with the inside pane flush mounted.
5.Multiple windows are located along the tunnel so that the entire
length of the test sample is observable from outside the fire
chamber.
6.The lid is consist of a removable noncombustible metal and
mineral composite structure.
7.The lid covers the fire test chamber and the test samples
maintains in an unwarped and flat condition.
8.Two NFP elbow gas burners delivering flames upward against the
surface of the test samples.
9.Remote spark ignition mode, to ensure the safety.
10.An air intake shutter is located upstream of the burner.
11.Six refractory firebricks along the side walls of the chamber
for proper combustion.
12.The static pressure meter inserted through the top at the
midwidth of the tunnel below the ceiling.
13.The exhaust end is fitted with a gradual rectangular-to-round
transition piece.
14.The exhaust duct is insulated with high temperature mineral
composition material.
15.An exhaust fan is installed at the end of the exhaust duct.
16.The air flow and draft pressure are controlled by automatically
damper and Frequency converter.
17.A photometer system consisting of a lamp and photocell mounted
on a horizontal section, and with the light beam directed upward
along the vertical axis of the vent pipe.
18.Thermocouples installed inside and outside the floor of the test
chamber.
19.Data acquisition system and software.
1. The stainless steel combustion test box body has a brick
structure inside, which can resist the flame impact and has good
thermal insulation performance;
2. Double-layer quartz glass observation window, can observe the
flame spread distance, and record;
3. Using the indicator light recording method, the flame spread
distance can be recorded more intuitively;
4. The cooling water circulation support bracket can support the
combustion cover such as calcium silicate board;
5. Equipped with 2mm thick 304 stainless steel water seal groove to
ensure that the smoke does not leak during the test;
6. 304 stainless steel insulation body cover, filled with high
temperature insulation material;
7. Equipped with an escalator sample installation platform to
facilitate the installation, removal of samples and inspection of
the furnace;
8. Independent multi-function exhaust pressure detecting device:
real-time monitoring of exhaust pressure changes during testing.
Detection range 0~250Pa, accuracy ±0.5Pa, system indication
pressure test accuracy ±2Pa;
9. Fan: 380V, 50Hz, 3Kw equipped with frequency converter can
change the wind speed, the flow rate is at least 8000m3/h, and the
flue gas generated by the sample combustion can be discharged out
of the room in time to ensure the safety of the test;
10. Double-head gas burner: It can output standard 5.3MJ/min heat,
and can control the gas flow rate by mass flow meter according to
different standards. The measuring range is 0~160L/min, which can
change the calorific value output of the burner and the maximum
output. Energy up to 100MJ/min;
11. Automatic ignition system: to ensure the safety of the test,
high-voltage igniter, 44KV, 50mA, the minimum high voltage of the
ignition electrode is 1.8kVp;
12. Smoke density system: Provide a separate signal processing
system to ensure that the sensor is linear;
13. Automatically record temperature and smoke sensing signals, and
the sample collection frequency is 1 Hz;
14. Mass flow controller: 316 stainless steel material, the maximum
pressure of 1000psig (70bar), leakage rate is less than 1 × 10-7sml
/ s, NIST calibration, 0 ~ 5VDC and 4 ~ 20mA signal, loop
protection, propane flow range 0 ~ 2.3g / s, control speed ≤ 2s,
control accuracy of ± 1% FS, repeatability ± 0.5FS, temperature
range 0 ~ 50 ° C, humidity range 0 ~ 90%, digital display,
automatic The gas supply meets the 5000Btu (5.3MJ)/min heat
requirement during the control test, and the software automatically
records the amount of gas used;
15. Standard test software can automatically record test data such
as system wind speed, temperature and smoke density.
UL910/NFPA262 Steiner horizontal tunnel furnace is mainly used for the flame retardant performance test of CMP grade wire and cable. It is mainly used for cables in horizontal subsystems that are directly laid in ventilation or forced ventilation without metal pipelines. The flame retardant test standard represents the most stringent flame retardant test standard for UL and even the entire wire and cable flame retardant test. Only the fluorine material sheath cable can pass the flame retardant test method. Due to the high decomposition temperature of fluoroplastics (greater than 400 degrees), the ignition point is also high (800 degrees or more), and it is not easy to burn when the fire is not strong, so it has better fire resistance than other organic materials.
The purpose of this test is to determine whether the flame-propagation and smoke-generating characteristics of cables without raceways are within the limits specified in the National Electrical Code (NEC). Cables having adequate fire-resistant and low-smoke-producing characteristics need not comply with general wiring methods when the cables are installed (without raceways) in environmental-air ducts, concealed hollow building spaces used as ducts for environmental air, and other environmental-air-handling spaces not specifically excluded (areas involving grease and flammable dust, vapor, and the like). This test method is essentially the same as the test method described in the Standard Method of Test for Fire and Smoke Characteristics of Wires and Cables, NFPA 262.
Application:It is mainly used for cables in horizontal subsystems that are directly laid in a ventilated or forced air environment without using metal pipelines.
Standards:NFPA 262 UL910
Dimension:21300 mm (L) x 1100 mm (D) x 2100 mm (H)
Weight:1770kg
Electrical: 115 Volts AC 60Hz / 230 Volts AC 50Hz.
Installation requirements
Electrical: 380 Volts AC, 20KW
Ambient Temperature: Operating 15°C to 35°C.
Gas: Methane and air compressor
Utility: Crane
Steiner Tunnel Test Apparatus.pdf
What does the Steiner tunnel test assess?
Steiner Tunnel tests measure the surface burning characteristics of interior finish materials and assemblies used in buildings, which is critical to understanding how materials react during a fire.
SKYLINE INSTRUMENTS CO.,LTD
SKYLINE (DONGGUAN SKYLINE INDUSTRIAL CO.,LTD) provides full line of Toys Testing Equipment, Fire Testing Equipment ,Flammability Testing Equipment,Tensile Test Machine, Furniture Testing Machines ,Textile Testing Equipment and other lab test equipment .We also offers value added support services like lab layout, calibration testing procedures / standards, recording techniques and operations of equipment, etc. We have agents to support you in over 10 countries around the world. With a network of representatives providing sales and technical support world-wide.
SKYLINE has achieved good repute in the fields of Fire Testing
Equipment, Footwear Testing Equipment, Toy Testing Equipment,
Furniture Testing and other lab test equipment.
SKYLINE focus on the lab testing equipment for decads and we manufacturers the testing instrument as per the international standards like EN71, ASTM, IS 8124 and SRS.
Our major customers are BV, ITS, TUV, SGS, Hasbro and SASO, For these customer 100% testing instruments are supplied by SKYLINE and we are the continuous supplier for these lab. Since SKYLINE is a manufacturer design/develop with advanced technology and having well experienced Technicians which will provide high quality service after sale.
Our main products
Lab Testing Equipment
Flammability Testing Equipment
Fire Testing Equipment
Wire and Cable Fire Tester
Building Material Fire Tester
Toys Testing Equipment
Environmental Test Chamber
Textile Testing Equipment
Furniture Test Machine
Mattress Testing Machine
Temperature And Humidity Test
Our Service
Testing Equipment Design and manufacture
Test Lab Planning and Establish
Toys Test Equipment Upgrade
Toys Test Equipment operation Training
Toys Finish Goods and Mattress Inspection
Acting for Customer Testing and Certifying
Acting for Foreign Trading Company Quality Inspection
Please have a look at our website and don’ t hesitate to contact us
if any items catch your interest. We will do our best to meet your
requirement.
Thank you for visiting. We look forward to your inquiry to carry
forward win-win cooperation with you soon.