Cat.6 UTP Outdoor Gel Filled Direct Burial Cable
UTP, 4-pair with rip cord
Polyolefin Jacket, UV Resistant
Gel filled (Non Conductive)
Supports all applications designed to operate over category 6 or lower rated systems.
Number of Pairs | 4 | Color Code: Pair 1: Blue-White/Blue Pair 2: Orange-White/Orange Pair 3: Green-White/Green Pair 4: Brown-White/Brown Packaging:305m reel in box |
Conductor | Solid Copper Ø 0.56 mm | |
Insulation | HDPE | |
Separator: | cross filler | |
screen | PET tape | |
rip cord (optical) | yes | |
Water Proof | Gel filled | |
Outer sheath | uv resistant Linear low-density polyethylene | |
thickness of outer sheath | 0.55 mm | |
cable outer diameter | 6.3 mm | |
Colour | balck |
Length: Cable weight: Wire size: Overall outside diameter: | 1000 ft/305 m 14~15 kg 23 AWG (Ø 0.56 mm) 6.3 mm |
ANSI/TIA Category Characteristic Impedance (Frequency: 1-200 MHz) DC Resistance Unbalance, maximum DC Resistance , maximum at 20˚C Propagation delay at100 MHz (ns/100m) Delay Skew Mutual Capacitance Nominal Velocity of Propagation (NVP) Coupling attenuation at 30˚C Operating Frequency, maximum | 6 100 ± 15 ohms 5 % 9.38 ohms/100 m <536 ≤35 ns 5.6 nF/100 m @ 1 kHz 69% 45MHz(dB) 250 MHz |
Frequency | Attenuation | NEXT (Min) | PS NEXT (Min) | ELFEXT (Min) | PS ELFEXT (Min) | Attenuation (Max) | TCL (Min) | PS ANEXT (Min) | PS AACR-F (Min) | RL (Min) |
MHz | dB/100m | dB | dB | dB/100m | dB/100m | dB | dB | dB | dB | dB |
4 | 4.2 | 66.3 | 63.3 | 56 | 53 | 3.8 | 44 | 67 | 66.2 | 23 |
8 | 5.9 | 61.8 | 58.8 | 49.9 | 46.9 | 5.3 | 41 | 67 | 60.1 | 24.5 |
10 | 6.6 | 60.3 | 57.3 | 48 | 45 | 5.9 | 40 | 67 | 58.2 | 25 |
16 | 8.3 | 57.2 | 54.2 | 43.9 | 40.9 | 7.5 | 38 | 67 | 54.1 | 25 |
20 | 9.3 | 55.8 | 52.8 | 42 | 39 | 8.4 | 37 | 67 | 52.2 | 25 |
25 | 10.5 | 54.3 | 51.3 | 40 | 37 | 9.4 | 36 | 67 | 50.2 | 24.3 |
31.25 | 11.7 | 52.9 | 49.9 | 38.1 | 35.1 | 10.5 | 35.1 | 67 | 48.3 | 23.6 |
62.5 | 16.9 | 48.4 | 45.4 | 32.1 | 29.1 | 15 | 32 | 65.6 | 42.3 | 21.5 |
100 | 21.7 | 45.3 | 42.3 | 28 | 25 | 19.1 | 30 | 62.5 | 38.2 | 20.1 |
200 | 31.7 | 40.8 | 37.8 | 22 | 19 | 27.6 | 27 | 58 | 32.2 | 18 |
250 | 35.9 | 39.3 | 36.3 | 20 | 17 | 31.1 | 26 | 56.5 | 30.2 | 17.3 |
300 | 39.8 | 38.1 | 35.1 | 18.5 | 15.5 | 34.3 | / | 55.3 | 28.7 | 17.3 |
400 | 46.9 | 36.3 | 33.3 | 16 | 13 | 40.1 | / | 53.5 | 26.2 | 17.3 |
500 | 53.4 | 34.8 | 31.8 | 14 | 11 | 45.3 | / | 52 | 24.2 | 17.3 |
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20˚C.
1. copper rod | 2. wire drawing | 3. Annealing |
4. Core insulation | 5. Wire twisting | 6. wire backing twisting |
7. Cabling | 8. Jacking | 9. Packing |
Shenzhen Chengtiantai Cable Industry Development Co.,Ltd